RC beams strengthened with prestressed FRP plates

The application of prestressed fiber reinforced polymer (FRP) plates to the reinforcement and repair of civil structures can improve the engineering efficiency and the stress state of members.

2018-09-12 18:44:06

Beams Strengthened with Prestressed CFRP Strip

Reinforcement of reinforced concrete members with embedded prestressed FRP plates can significantly improve the mechanical properties of reinforced concrete members, and its mechanism and effect are similar to that of external prestressed FRP plates.

2018-09-12 17:52:05

Two layer CFRP reinforcement

Compared with single-layer CFRP, double-layer CFRP bears higher tensile stress, so it needs higher performance colloid to ensure the overall force.

2018-09-12 16:36:21

Structural strengthening, these are the key points!

Structural strengthening, these are the key points! Foundation treatment, bond steel plate reinforcement, rebar anchorage, carbon fiber fabric reinforcement​, crack repair

2018-09-11 18:08:51

Bearing capacity reinforcement and seismic strengthening

Structural strengthening can not only improve the bearing capacity and durability of the structure, but also improve the seismic capacity. So can it be considered that conventional structural strengthening can simultaneously enhance the bearing capacity and seismic capacity, the two can be treated the same?

2018-09-11 17:02:41

Why use small PAN tow fiber for structural reinforcement?

The tensile strength of the tow is very stable, the dispersion is small, and the coefficient of variation is below 5%. It is easy to control the performance and quality of the tow effectively in the process of production and use.

2018-09-11 16:33:09

Strengthening concrete beams with FRP composite

At present, it is very common to use carbon fiber reinforced polymer (CFRP) composite to reinforce bridges, especially when the structure is in corrosive environment, it is more suitable to use this kind of composite material to reinforce bridges.

2018-09-06 18:26:42

The 'k' number of carbon fiber fabric

We can tell ourselves how much K the carbon fiber fabric is. You can do it yourself !!

2018-09-17 15:27:10

Structural retrofitting using FRP laminates

Cut the precured FRP laminate according to the design size. When cutting, some carbon fiber laminate should be lengthened about 150 mm for normal tensile bond strength test, taking into account the need of field inspection.

2018-09-06 16:00:32

The effect of bonding steel plate reinforcement

If the area of a single empty drum is less than 10,000 mm2, it can be repaired by filling glue with borehole injection method; if the area of a single empty drum is more than 10,000 mm2, it should be removed and re-pasted steel plate with structural bonding adhesive, and re-checked and accepted.

2018-09-06 15:35:51
Back
Top
Close